Search Results for

    Show / Hide Table of Contents

    TestContext

    Each NUnit test runs in an execution context, which includes information about the environment as well as the test itself. The TestContext class allows tests to access certain information about the execution context.

    Note

    It's important to remember that "test" in NUnit may refer to an individual test cases or a suite such as a TestFixture. Within a test method, SetUp method or TearDown method, the context is that of the individual test case. Within a OneTimeSetUp or OneTimeTearDown method, the context refers to the fixture as a whole. This can lead to confusion, since most runners display information about fixtures differently from test cases. In fact, some runners may not display information about fixtures at all!

    Static Properties

    CurrentContext

    Gets the context of the currently executing test. This context is created separately for each test before it begins execution. See below for properties of the current context.

    Out

    Gets a TextWriter used for sending output to the current test result.

    If output written by your code never shows up, or shows up under a different test, see Capturing output from other threads and hosted applications below.

    Error

    Gets a TextWriter used for sending error output intended for immediate display.

    Progress

    Gets a TextWriter used for sending normal (non-error) output intended for immediate display.

    TestParameters

    Test parameters may be supplied to a run in various ways, depending on the runner used. For example, the console runner provides a command-line argument and v3.4 of the NUnit 3 VS Adapter will supports specifying them in a .runsettings file. The static TestParameters property returns an object representing those passed-in parameters.

    The TestParameters object supports the following properties:

    • Count - The number of parameters.
    • Names - A collection of the names of the supplied parameters.
    • this[string name] - The value of a parameter. In Vb, use Item.

    The TestParameters object supports the following methods:

    • Exists(string name) - Returns true if a parameter of that name exists.
    • Get(string name)- Returns the same value as the indexer.
    • Get<T>(string name, T defaultValue) - Returns the value of the parameter converted from a string to type T or the specified default if the parameter doesn't exist. Throws an exception if conversion fails.

    Note that all parameter values are strings. You may convert them to other Types using the generic Get method listed above or using your own code. An exception may be thrown if the supplied value cannot be converted correctly.

    Static Methods

    Write

    Writes text to the current test result, that is the Out writer. Prefer to use the Out writer directly for better clarity.

    Note: These methods will be deprecated in the future

    Write(bool value)
    Write(char value)
    Write(char[] value)
    Write(double value)
    Write(Int32 value)
    Write(Int64 value)
    Write(decimal value)
    Write(object value)
    Write(Single value)
    Write(string value)
    Write(UInt32 value)
    Write(UInt64 value)
    Write(string format, object arg1)
    Write(string format, object arg1, object arg2)
    Write(string format, object arg1, object arg2, object arg3)
    Write(string format, params object[] args)
    

    WriteLine

    Writes text to the current test result, followed by a newline, that is the Out writer.
    Prefer to use the Out writer directly for better clarity.

    Note: These methods will be deprecated in the future

      WriteLine()
      WriteLine(bool value)
      WriteLine(char value)
      WriteLine(char[] value)
      WriteLine(double value)
      WriteLine(Int32 value)
      WriteLine(Int64 value)
      WriteLine(decimal value)
      WriteLine(object value)
      WriteLine(Single value)
      WriteLine(string value)
      WriteLine(UInt32 value)
      WriteLine(UInt64 value)
      WriteLine(string format, object arg1)
      WriteLine(string format, object arg1, object arg2)
      WriteLine(string format, object arg1, object arg2, object arg3)
      WriteLine(string format, params object[] args)
    

    AddFormatter (3.2+)

    Adds a formatter for values based on some criterion, such as the Type of the value. The provided formatter will be used when an expected or actual value needs to be displayed as part of a message from a constraint.

    AddFormatter(ValueFormatter formatter);
    AddFormatter(ValueFormatterFactory formatterFactory);
    

    Both ValueFormatter and ValueFormatterFactory are delegates. ValueFormatter takes a single object as an argument and returns its string representation. The AddFormatter overload that takes a ValueFormatter is intended for use in most cases that arise.

    AddTestAttachment (3.7+)

    Attaches a file, with optional description, to the current test.

    AddTestAttachment(string filePath, string description = null);
    

    The file will be attached to the test result in the xml report. Test runners, such as the NUnit 3 VS Adapter, may also present the file to the user.

    Notes:

    1. The file must exist at the time of attachment.
    2. File paths will be resolved as fully rooted paths, relative to TestContext.CurrentContext.WorkDirectory, which can be set by the user.

    Properties of the CurrentContext

    Test

    Gets a representation of the current test, with the following properties:

    • ID - The unique Id of the test
    • Name - The name of the test, whether set by the user or generated automatically
    • Namespace - The namespace of the test
    • DisplayName - The display name of the test
    • FullName - The fully qualified name of the test
    • MethodName - The name of the method representing the test, if any
    • Method - The IMethodInfo of the test method
    • Type - The TypeInfo of the test
    • ClassName - The classname of the test
    • Arguments - The arguments as a list of objects, if any.
    • ExpectedResult - The expected result, if that is set for the test
    • Properties - An IPropertyBag of the test properties. Note: The Get method ONLY returns the first property (with a given key) for the current level.

    The following properties are in version 4.2 and above.

    • Parent - The parent of the given test.
    • AllPropertyValues - Returns a list of values (as objects) for a given property across the complete test hierarchy
    • AllCategories - Returns a list of all categories (as strings) across the complete test hierarchy
    • PropertyHierarchy - A utility method which returns the complete hierarchy of all properties including the name, value and level where they are found.

    Result

    Gets a representation of the test result, with the following properties:

    • Outcome - A ResultState representing the outcome of the test. ResultState has the following properties:
      • Status - A TestStatus with four possible values:
        • Inconclusive
        • Skipped
        • Passed
        • Warning
        • Failed
      • Label - An optional string value, which can provide sub-categories for each Status. See below for a list of common outcomes supported internally by NUnit.
      • Site - A FailureSite value, indicating the stage of execution in which the test generated its result. Possible values are
        • Test
        • SetUp
        • TearDown
        • Parent
        • Child
    • Assertions - A list of AssertionResult values generated up to this point in the test. Please note that only failed assertions will be stored in here to limit the size of the result tree and potential impact on performance. Each AssertionResult has the following properties:
      • Status - An AssertionStatus with five possible values:
        • Inconclusive
        • Passed
        • Warning
        • Failed
        • Error
      • Message - A string containing the message produced by the assertion (possibly null).
      • StackTrace - A string containing the stack trace associated with the assertion.
    • PassCount - An int representing the number of test cases that passed when running the test and all its children.
    • FailCount - An int representing the number of test cases that failed when running the test and all its children.
    • SkipCount - An int representing the number of test cases that were skipped when running the test and all its children.
    • InconclusiveCount - An int representing the number of test cases that were inconclusive when running the test and all its children.
    • StackTrace - A string containing the stack trace associated with an error or failure.
    • Message - A string containing the message associated with a test failure or with not running the test.

    Although the outcome of the test may be accessed during setup or test execution, it only has a useful value in the teardown stage.

    Common Outcomes

    The following is a list of outcomes currently produced by NUnit. Others may be added in the future.

    • Success: the test passed. (Status=Passed)
    • Inconclusive: the test was inconclusive. (Status=Inconclusive)
    • Failure: a test assertion failed. (Status=Failed, Label=empty)
    • Error: an unexpected exception occurred. (Status=Failed, Label=Error)
    • NotRunnable: the test was invalid and could not be run. (Status=Failed, Label=Invalid)
    • Cancelled: the user cancelled while this test was running. (Status=Failed, Label=Cancelled)
    • Ignored: the test was ignored. (Status=Skipped, Label=Ignored)
    • Explicit: the test was not run because it is marked Explicit. (Status=Skipped, Label=Explicit)
    • Skipped: the test was skipped for some other reason. (Status=Skipped, Label=empty)

    ActiveTests

    Note

    This property was added in NUnit 5.0.

    Gets the list of test cases under the current suite that will run, after any filter has been applied. It is available in OneTimeSetUp and OneTimeTearDown methods, and returns null everywhere else.

    This lets a SetUpFixture or a fixture skip expensive setup, such as starting a database, when none of the tests that need it will run. It works the same way with every runner, for example dotnet test, the NUnit Console or an IDE.

    [SetUpFixture]
    public class DatabaseSetUp
    {
        private bool _databaseStarted;
    
        [OneTimeSetUp]
        public void StartDatabaseIfNeeded()
        {
            // ActiveTests lists the test cases under this namespace that passed the filter
            var activeTests = TestContext.CurrentContext.ActiveTests ?? [];
    
            // Only do the expensive setup if at least one active test needs it
            if (activeTests.Any(test => test.Properties["Category"].Contains("Database")))
            {
                _databaseStarted = true; // Start the database here
            }
        }
    
        [OneTimeTearDown]
        public void StopDatabase()
        {
            if (_databaseStarted)
            {
                _databaseStarted = false; // Stop the database here
            }
        }
    }
    
    [TestFixture]
    public class CustomerTests
    {
        [Test, Category("Database")]
        public void CanSaveCustomer() => Assert.Pass();
    
        [Test]
        public void CanFormatCustomerName() => Assert.Pass();
    }
    

    TestDirectory

    Gets the full path of the directory containing the current test assembly.

    WorkDirectory

    Gets the full path of the directory to be used for output from this test run. The XML result file and any redirected output files are located under this directory. This is normally the directory that was current when execution of NUnit began but may be changed by use of the --work option of nunit-console.

    Random

    Returns a Randomizer object, which may be used in the test code to generate random values. These values are repeatable on reruns of the tests so long as (a) the test assembly is not changed and (b) the same seed is used. The initial random seed used in any test run may be found in the XML result file and may be provided to a subsequent run on the command line.

    See Randomizer Methods for details about each available random data type.

    Capturing output from other threads and hosted applications

    Anything your test writes with Console.WriteLine, TestContext.Out or an ILogger normally ends up in the output of the test that is running. That is still true after an await, inside Task.Run, and on threads the test starts itself. It stops being true when the code that writes runs somewhere NUnit cannot connect back to the test:

    • inside an application hosted by WebApplicationFactory, the usual set-up for ASP.NET Core integration tests
    • on a server that listens on a real port and handles requests on its own threads
    • in a separate process

    Output from those places is silently lost or, when a shared host is used by several tests, shows up under the wrong test. The sections below show how to fix each case. The reason it happens is explained in In-Depth Technical Explanation at the end of this page.

    ASP.NET Core integration tests with WebApplicationFactory

    This is the most common way to hit the problem: Console.WriteLine, TestContext.Out.WriteLine and ILogger calls made inside a request handler or middleware never appear in the test output, or the application's console logging appears under whichever test happened to start the host first.

    The in-memory TestServer behind WebApplicationFactory has a setting for exactly this situation, PreserveExecutionContext. Turn it on in your factory and every request is attributed to the test that sent it:

    public sealed class TestWebApplicationFactory : WebApplicationFactory<Program>
    {
        protected override void ConfigureWebHost(IWebHostBuilder builder)
        {
            // Flow the calling test's ExecutionContext, and with it NUnit's test context,
            // into the in-memory server so that output written while handling a request
            // is attributed to the test that sent the request.
            builder.ConfigureServices(services =>
                services.Configure<TestServerOptions>(options => options.PreserveExecutionContext = true));
        }
    }
    

    It does not matter whether the factory is created in the test body, in [SetUp] or in [OneTimeSetUp]. A single factory and client shared by the whole fixture still gives each test its own output:

    public class SharedFactoryTests
    {
        private TestWebApplicationFactory _factory = null!;
        private HttpClient _client = null!;
    
        [OneTimeSetUp]
        public void CreateFactory()
        {
            _factory = new TestWebApplicationFactory();
            _client = _factory.CreateClient();
        }
    
        [OneTimeTearDown]
        public void DisposeFactory()
        {
            _client.Dispose();
            _factory.Dispose();
        }
    
        [Test]
        public async Task HandlerOutputAppearsUnderThisTest()
        {
            var body = await _client.GetStringAsync("/");
    
            // The Console.WriteLine and ILogger output written by the request handler
            // is part of this test's output, even though the factory is shared.
            Assert.That(body, Is.EqualTo("Hello from the application"));
        }
    
        [Test]
        public async Task HandlerOutputAppearsUnderThisOtherTest()
        {
            var body = await _client.GetStringAsync("/");
    
            Assert.That(body, Is.EqualTo("Hello from the application"));
        }
    }
    

    If you cannot derive from the factory, set the property on the server before creating a client:

    [Test]
    public async Task SetThePropertyOnTheServerBeforeCreatingAClient()
    {
        await using var factory = new WebApplicationFactory<Program>();
        factory.Server.PreserveExecutionContext = true;
    
        using var client = factory.CreateClient();
        var body = await client.GetStringAsync("/");
    
        Assert.That(body, Is.EqualTo("Hello from the application"));
    }
    

    With the setting on, Console.WriteLine, TestContext.Out and TestContext.Progress inside the application behave exactly as they do in the test method, and the application's ILogger output, including the default console logger, lands in the right test too. The application used by these examples is an ordinary minimal API with no reference to NUnit:

    var builder = WebApplication.CreateBuilder(args);
    var app = builder.Build();
    
    app.MapGet("/", (ILogger<Program> logger) =>
    {
        Console.WriteLine("Console.WriteLine from inside the request handler");
        logger.LogInformation("ILogger output from inside the request handler");
        return "Hello from the application";
    });
    
    app.Run();
    
    // Makes the implicit Program class visible to WebApplicationFactory<Program> in the test project.
    public partial class Program;
    

    Servers on their own threads or in another process

    PreserveExecutionContext only helps with the in-memory TestServer. When the application listens on a real Kestrel endpoint, for example for browser tests with Playwright or Selenium, or runs as a separate process, NUnit has no way to connect the server's threads to the test. You then have two options.

    The first is to give the application a writer instead of relying on NUnit to find the test. A TextWriter obtained from TestContext.Out while the test is running stays bound to that test, no matter which thread later writes to it. An ILoggerProvider that writes to such a writer gets the application's logging into the test output:

    /// <summary>
    /// Forwards ILogger output to a TextWriter chosen by the test, such as TestContext.Out.
    /// </summary>
    public sealed class TextWriterLoggerProvider(TextWriter writer) : ILoggerProvider
    {
        public ILogger CreateLogger(string categoryName) => new TextWriterLogger(categoryName, writer);
    
        public void Dispose()
        {
        }
    
        private sealed class TextWriterLogger(string category, TextWriter writer) : ILogger
        {
            public IDisposable? BeginScope<TState>(TState state)
                where TState : notnull => null;
    
            public bool IsEnabled(LogLevel logLevel) => logLevel >= LogLevel.Information;
    
            public void Log<TState>(LogLevel logLevel, EventId eventId, TState state, Exception? exception,
                Func<TState, Exception?, string> formatter)
            {
                writer.WriteLine($"{logLevel} {category}: {formatter(state, exception)}");
            }
        }
    }
    
    [Test]
    public async Task OutputFromARealServerGoesToTheWriterCapturedByTheTest()
    {
        var builder = WebApplication.CreateBuilder();
        builder.WebHost.UseUrls("http://127.0.0.1:0"); // Kestrel on a free loopback port
    
        // Capture the writer here, while this test's context is current. The writer
        // stays bound to this test no matter which thread later writes to it.
        builder.Logging.ClearProviders();
        builder.Logging.AddProvider(new TextWriterLoggerProvider(TestContext.Out));
    
        await using var app = builder.Build();
        app.MapGet("/", (ILogger<RealServerTests> logger) =>
        {
            logger.LogInformation("Handled a request on a Kestrel thread");
            return "Hello from Kestrel";
        });
        await app.StartAsync();
    
        using var client = new HttpClient();
        var body = await client.GetStringAsync(app.Urls.First());
    
        Assert.That(body, Is.EqualTo("Hello from Kestrel"));
    }
    

    Capture the writer per test, in the test body or in [SetUp]. A writer captured in [OneTimeSetUp] belongs to the fixture rather than to any test case, and most runners do not display fixture-level output, so the messages disappear again.

    The second option is to restore NUnit's test context inside the application. The community package Agoda.NUnit.KestrelLogging adds middleware that does this for the test that created the factory. It is mentioned here as an example rather than an endorsement. It has the same limitation as the captured writer: it works when the factory is created in the test body or in [SetUp], but not when a shared factory is created in [OneTimeSetUp].

    In-Depth Technical Explanation

    NUnit decides which test a piece of output belongs to by looking at the current TestExecutionContext, which .NET carries in an AsyncLocal as part of the ExecutionContext. Console.Out, TestContext.Out, TestContext.Progress and TestContext.Error all consult that context when they are written to. The ExecutionContext flows automatically across await, Task.Run, thread pool work items and threads started from the test, which is why output written in any of those places is captured as usual.

    The context cannot reach code that runs where the test's ExecutionContext was never flowed to: a thread or hosting pipeline that was started outside the test, or anything on the far side of a socket. When NUnit finds no test context it uses an ad hoc placeholder context instead. Console.WriteLine then goes to the original console, TestContext.Out writes to a result that no runner reports, and Progress and Error are discarded. If a long-lived background thread inherited the context of an earlier test, its output is attributed to that earlier test.

    WebApplicationFactory<TEntryPoint> hosts the application on an in-memory TestServer, and by default TestServer deliberately does not flow the caller's ExecutionContext into the request pipeline. Request handlers, middleware and the application's ILogger calls therefore run in NUnit's placeholder context. PreserveExecutionContext tells TestServer to flow the caller's ExecutionContext into each request, which carries NUnit's test context with it. Because the context is captured per request rather than when the host is built, a factory created in [OneTimeSetUp] still attributes each request to the test that sent it.

    A TextWriter returned by TestContext.Out is bound to the test result that was current when it was obtained, so it keeps working from threads that have no test context. The Agoda.NUnit.KestrelLogging middleware instead re-attaches the TestExecutionContext that was current when the factory was created, which relies on NUnit internals. Both approaches fail for a shared factory created in [OneTimeSetUp] because every test case gets its own output writer, and the one captured during [OneTimeSetUp] belongs to the fixture.

    The original investigation and a repro are in nunit/nunit#5067.

    • Edit this page
    In this article
    Back to top Generated by DocFX | Copyright (c) 2018- The NUnit Project - Licensed under CC BY-NC-SA 4.0